A multi-purpose welding machine for all electrofusion fittings operating at an AC welding voltage of 8–48 V. The machine is equipped with an optical barcode reader (scanner) for reading the welding code according to ISO 13950, and performs the welding cycle as defined by the fitting manufacturer.
Welding can also be carried out by entering the welding data (time and voltage) manually, but manual entry does not guarantee good welding results and should be used in emergencies only. The ambient temperature sensor is located on the welding cable.
I-PLAST 60 Electrofusion Control Unit
Use
The machine is designed for building systems that carry fluids under pressure and without pressure: gas, water and industrial fluids.
To ensure proper welding, the machine was developed with a unique internal control system. Throughout the welding cycle, 4 times per second, it monitors all the electrical welding parameters – voltage, current and resistance – within a tolerance of ±1.5%.
Additional technical features allow connection to and proper operation with generators that have mechanical or electronic voltage regulation. Data stored in memory can be transferred to other devices via USB.
Range of use
- Plastitalia electrofusion fittings: all types, up to 400 mm in diameter.
- Electrofusion fittings from other manufacturers: see the duty cycle in the technical data table.
Standards
The equipment complies with ISO 12176-2/3/4, DVS 2207, ECE1 and UNI 10566.
Technical data
| Category | Item / feature | Value / description | |
| Technical data | Classification CEI EN 60335-1 | Class I electronic device | |
| Classification ISO 12176-2 | P23 US VAK DX | ||
| Maximum welding diameter | 400 mm (PLASTITALIA fittings) | ||
| Weldable material | PE/PEX/PP/PP-R | ||
| Fusion parameter input | Scanner / manual | ||
| Input voltage | 230 V AC, (185 V-260 V) | ||
| Input current | 16 A | ||
| Input frequency | 50 Hz (40-70 Hz) | ||
| Voltage to fittings | 8-48 V AC | ||
| Duty cycle at | 100%≡50 A 60%=70 A 30%=90 A |
|
|
| Peak output | 100 A (electronically limited) | ||
| Rated power | 2500 W 12 | ||
| Operating temperature range | -10 to +50 |
|
|
| Protection rating | IP54 | ||
| Weight (including cables) | 18.5 kg | ||
| Input cable | Length 3.0 m. Fitted with a 16 A Schuko plug | ||
| Welding cable | 3.0 m | ||
| Pin diameter | 4 mm (adaptor from 4.7 mm) | ||
| Display | Graphic, 128×64 pixel resolution, backlit | ||
| Monitored parameters – input | Voltage / power / frequency | ||
| Monitored parameters – output | Voltage / resistance / contact / short circuit / current | ||
| Monitored parameters – other | Software / operating temperature / service | ||
| Error messages | Text / acoustic signals | ||
| Included | USB memory stick, carrying bag, manual | ||
| Memory | Number of reports | 7500 | |
| Interface | USB/RS232 | ||
| Data format | CSV-TXT (convertible to any format) | ||
| Stored information – welding data | Voltage / current / nominal and actual fusion time / status / resistance / error messages | ||
| Stored information – fitting data | Barcode information (ISO 13950) / type / size / manufacturer | ||
| Stored information – welding machine | Serial number / inventory number / last service data / operating hours / software | ||
| Stored information – welder | Barcode (Plastitalia or ISO 12176-3) with function control: identification, manual setting | ||
| Traceability functions – welder code | ISO-12176-3 | ||
| Traceability functions – weather conditions | DVS 2207/2208 | ||
| Traceability functions – welding barcode | ISO 13950 | ||
| Traceability functions – fitting traceability code | ISO 12176-4 | ||
| Traceability functions – first pipe traceability code | ISO 12176-4 | ||
| Traceability functions – second pipe traceability code | ISO 12176-4 | ||
| Traceability functions – third pipe traceability code / info text | ISO 12176-4 | ||
| Accessories | Supplied accessories | Manual scraper | |
| Optional accessories |
16 A plug (IEC 309); Barcode reader (optical) |